| Instalation type | Fixed instalation |
|---|---|
| Control panel power supply / frequency / fuse | ~ 110-230 V/50-60 Hz, max. 0.28 A with F1.6 A/250 V fuse, protection class II |
| Power / current | max 23 VA / 0.1 A |
| Protection class | II. |
| Back-up battery | 12 V; 2.6 Ah max (lead gel) |
| Low backup battery voltage (fault indication) | ≤11 V |
| Maximum battery recharge time (80% capacity) | 72 h |
| Bus supply voltage / max ripple (red - black) | 12.0 ÷ 13.8 VDC / ±100 mV |
| Max. continuous consumption from control panel | 1000 mA |
| - with 12 h backup (2.6 Ah battery) | Without GSM communicator | LAN - off: 115 mA | LAN - on: 88 mA |
| With GSM communicator | LAN - off: 80 mA | LAN - on: 53 mA | |
| Max. number of sections | 4 |
| Max. number of peripherals | 31 peripherals + 31 drivers |
| Max. number of users | 32 |
| Max. number of PG outputs | 2 |
| Alarm connections |
|
| Alarm device classification | Security level 2 / environment class II |
| - In accordance with | EN50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3 (using the radio module), EN 50131-10, EN 50136-1, EN 50136-2 |
| - Environment | Indoor general |
| - Operating temperature/humidity range | -10 °C to +40 °C/75% non-condensing |
| - Power supply | Type A - primary power supply with rechargeable backup battery |
| - Event memory capacity | of approx. 7 million recent events including source, date and time |
| - system response to loss of communication with periphery | Fault or Sabotage - depending on settings and profile
|
| - System reaction to incorrectly entered codes | after 10 incorrectly entered codes a sabotage alarm is declared and, depending on the selected profile, all control devices are blocked for 10 minutes. |
| - ATS classification | Supported ATS classes: SP2 - SP5, DP2 - DP4 SPT: Type Z Type of operation: Pass-through LAN on board: SP2 - SP5 (with IP protocol) JA-194Y LITE SP3 - SP5 (JABLO IP, ANSI SIA, DC-09) LAN + JA-194Y LITE DP2 - DP4 JABLO IP, ANSI SIA, DC-09) |
| - ATS alarm transmission protocols | JABLO IP, SIA IP, Contact ID, |
| - ATC security against substitution and information protection | Jablotron protocols: proprietary AES encryption with minimum 128-bit ANSI SIA key DC-09.2012 protocol with 128-bit AES encryption |
| LAN communicator | Ethernet interface CAT 5 (RJ-45) |
| Dimensions | 268 x 225 x 83 mm |
| Weight with/ without ACU | 1809 g/919 g |
| Basic parameters of the JA-111R module | 868.1 MHz, <25 mW, GFSK <80 kHz |
| Radio emission | ETSI EN 300 220-2 (JA-111R module) |
| EMC | EN 50130-4, EN 55032, ETSI EN 301 489-1, ETSI EN 301 489-3 |
| Electrical safety | EN IEC 62368-1 |
| Conditions of operation of the CTU radio module | ERC REC 70-03 |
| Certification body | TREZOR TEST (No. 3025) |