New JA-121PW bus motion detector combines PIR and microwave sensing for indoor use, covering up to 12 m with recommended installatio View larger

JAB JA-121PW Bus Dual PIR+MW Motion Detector

JA-121PW

New product

Bus motion detector with dual sensing (PIR + microwave) for indoor intrusion protection. Detection requires confirmation from both sensors to reduce false alarms. Coverage up to 12 m (PIR 110° / MW 90°); recommended mounting height 2.5 m. Settings via F‑Link; compatible with JA-103K and JA-107K.

More details

More info

Overview

The JAB JA-121PW is a bus-connected dual PIR + microwave (MW) motion detector designed for reliable indoor intrusion detection. The detector’s logic triggers an alarm only when the configured confirmation between the PIR and MW sensors is met, improving resistance to false triggers compared with PIR‑only units.

Installation and mounting

The device is intended for use within JABLOTRON systems and must be installed by a trained, certified Jablotron technician. Install vertically with the cover latch down at the recommended height of 2.5 m. Avoid mounting near large metallic surfaces or equipment that could reflect or shield the MW signal. Check for possible interference if multiple detectors are used in proximity.

Configuration and operation

All parameters are configured in the F‑Link software (Devices → Internal Settings). PIR and MW have separate immunity levels and MW sensitivity can be set to 100 %, 75 %, 50 % or 25 %. The MW confirmation mode can be limited to certain armed states, set always on, or disabled; MW‑only and PIR‑only modes are also available.

Key technical data

  • Power: from control panel bus 12 V DC (8–15 V)
  • Quiescent current: 1 mA; Max current: 10 mA
  • Recommended mounting height: 2.5 m
  • PIR coverage: 110° / up to 12 m
  • MW coverage: 90° / up to 12 m (can detect through thin non‑metallic obstacles)
  • Operating frequency (MW): 24.125 GHz; EIRP < 50 mW
  • Dimensions: 60 × 98 × 52 mm; Weight: 85 g
  • Operating temperature: -10 °C to +40 °C; Humidity: 75 % RH non‑condensing
  • Classification: Security level 2 / Environment class II (EN 50131‑1)

Perform a walk‑test and verify coverage with F‑Link diagnostics after installation. MW performance depends on room geometry and metallic objects; adjust sensitivity and immunity settings accordingly. Observe local regulations for microwave devices and follow the official Jablotron installation guide.